Positive Airway Pressure Device-manufacture,factory,supplier from China

(Total 24 Products for Positive Airway Pressure Device)
IntroductionAnaesthesia main unit:High resolution 5.5''  LCD screenClose,semi-close,semi-open systemApplication:Adult,PediatricLow gas alarming:Low O2 gas pressure,it will give alarming more than 7 secondsHigh pressure limitation:Whenever airway pressure exceed the pre-set high pressure,ventilator offers protection automatically, to assure airway pressure can not increaseanymore which supplies safety to patient.Low pressure protection:Once O2 pressure less than 0.1MPa, N2O gas supply was stoppedautomatically.Power failure alarming, power extendable function02 flush: 25~75 L/minGas
Contacta ahora
Technical SpecificationAnaesthesia main unit:High resolution 10.4" color TFT LCD screenDual-end pressure flow sensor,The unit can monitoring Tidal Volume,Respiratory frequency, airway pressure, pressure-time wave, flow-time wave (two-way),High Pressure limitation, Low Pressure limitation, Apnea,Oxygen concentration under both two operating mode (Auto、Manual)Respiration loop functionClose,semi-close,semi-openApplication: Adult, PediatricLow gas alarming: it gives alarming more than 7 seconds.High pressure Limitation: Whenever airway pressure exceed the pre-set High pressure,ventilator offe
Contacta ahora
Product descriptionAnaesthesia main unit:High luminance digital LED screenClose,semi-close,semi-open systemApplication:Adult,PediatricLow gas alarm: O2 gas pressure is low, alarm time exceeds 7 secondsHigh pressure limit: Whenever the airway pressure exceeds the preset high pressure,ventilator offers protection automatically, to assure airway pressure can not increaseanymore which supplies safety to patient.Power failure alarming,power extendable functionO2 flush:25~75L/minGas Pressure:O2:0.3~0.5MPaPower:220V±10%, 50Hz±1%Technology specificationFlow meter:O2 - dual tube(0.05~1L/min,1.1~10L/min
Contacta ahora
Product descriptionCompact structure, beautiful and exquisite, saving operating room spaceStainless steel table top, never rust, reduce maintenance costsTechnology specificationAnaesthesia main unit:■High luminance digital LED screen■Close,semi-close,semi-open system■Application:Adult,Pediatric■Low gas alarming:Low O2 gas pressure,it will give alarming more than 7 seconds■High pressure limitation:Whenever airway pressure exceed the pre-set high pressure,ventilator offers protection automatically, to assure airway pressure can not increase anymore which supplies safety to patient.■Power failure
Contacta ahora
Product descriptionContains Output interface for Anesthesia information management system.Complete with backup battery for working more than 120 minutes.Technology specification■High resolution 10.4'' TFT  LCD screen■Dual-end pressure flow sensor,The unit can monitoring tidal volume,respiratory frequency,airway pressure,pressure-time wave,flow-time wave(two-way),high pressure limitation,low pressurelimitation,apnea,oxygen concentration under both two operating mode(Auto,Manual)■Respiration loop function■Close,semi-close,semi-open and open(with bain circuit)■Application:Adult,
Contacta ahora
Product description This transport ventilator is a very important medical device that can provide patients with necessary breathing support in an emergency.
Contacta ahora
Procuct descriptionThis transport ventilator is a very important medical device that can provide patients with necessary breathing support in an emergency.
Contacta ahora
Product descriptionContains Output interface for Anesthesia information management system.Complete with backup battery for working more than 30 minutes.Technical SpecificationAnaesthesia main unit:■High resolution 8'' color TFT LCD screen■Dual-end pressure flow sensor,The unit can monitoring Tidal volume,Respiratory frequency,Airway pressure,Presssure-time wave,High pressure limitation,Low pressure Limitation,Apnea,Oxygen concentration under both operating mode(Auto,Manual)■Respiration loop function■Close,semi-close,semi-open system■Application:Adult,Pediatric■Low gas alarming:Low
Contacta ahora
Product descriptionModel S Anaesthesia Machine contains output interface for anesthesia information management system. Complete with backup battery for working more than 120 minutes.Product ParameterDual-end pressure flow sensor,The unit can monitoring tidal volume,respiratory frequency,airway pressure,pressure-time wave,flow-time wave(two-way),high pressure limitation,low pressure limitation,apnea,oxygen concentration under both two operating mode(Auto,Manual)Respiration loop functionClose,semi-close,semi-open and open(with bain circuit)Low gas alarming:it gives alarming more than 7
Contacta ahora
Product descriptionA high-brightness lighting device composed of high-power LED and its componentsThis product uses 80W LED as the light source. High luminous efficiency and high illumination.It is designed with a touch switch, brightness display, and electromagnetic compatibility switch power supply.Application: Hysteroscopy, Nasal Endoscopy, OtolaryngologyTechnical ParametersRated input power: 100WOptical output illumination value: >1600000LXLamp rated power: 80WColor temperature: 3000K-7000KColor rendering index: ≥90Lamp working life: ≥40000hTotal light: ≥500LmFAQQ1.
Contacta ahora
Product DescriptionAnesthetic Gas Scavenging System (AGSS) is a device used to remove anesthetic gases generated in operating rooms or other medical environments.Anesthetic gas is a medication used during surgery, usually delivered to patients through an anesthesia machine.However, some anesthesia gases may leak into the air of the operating room, posing potential health risks to medical staff and patients.The main function of AGSS is to collect and discharge anesthesia gases from the operating room through inhalation and filtration,in order to reduce the risk of personnel exposure to these ga
Contacta ahora
Product Details:Technical Parameters:1. Ambient temp. range: 5ºC~40 ºC;2. Relative Humidity Range: ≤80;3. Atmospheric Pressure Range: 86.0~106.0kpa;4. Power: 220V±22V,50Hz±1;5. Operating Freq.: 330~460kHz;6. Rated Power: 1100VA±10%;7. Type: CFPower Consumption: ≤1100VA (Cut function 400) Transportation and Storage:a),Ambient Temp.
Contacta ahora
Product Description1. 7" screen displays information area, alarm area, monitoring area, and setting area. 2. High precision mechanical flowmeter, instantly know the fresh gas flow to animals. 3. Vaporizer with temperature, pressure, flow compensation and self-lock function, keep safety anytime. 4. Real time pressure-time, flow-time oscillogram 5. Manual and mechanical ventilation for safer operation.6. External sensor design makes parameters setting more accurate. 7.
Contacta ahora
Product DescriptionMedical High Frequency Electrosurgical Unit with isolated output design, it provides proper power output for cutting and coagulating tissue in both monopolar and bipolar surgeries.It can meet the needs of many surgical operations. Adopting singlechip microcomputer control technology and modular design, it features simple design, convenient maintenance,powerful functions, stable performance and easy operation and is equipped with versatile jacks for accessories.Technology parameterRated output power:Pure cut: 1W~350W (Max.
Contacta ahora
Product descriptionType:The output of this machine is fully suspended, with two independent and isolated CF-type defibrillation-proof application parts (unipolar and bipolar), non-AP, APG-type common equipment, 220V±10% mains power supply.Function:The 416KHz (±10%) high-frequency current generated by this machine can perform surgical operations such as cutting and coagulation on biological tissues.
Contacta ahora
Product descriptionThe 416KHz (±10%) high frequency current generated by the machine can be used for biological tissue cutting, coagulation and other surgical operations, and has unipolar cutting: pure cutting, mixed cutting 1, mixed cutting 2; Unipolar solidification: spray solidification, soft solidification and standard bipolar six working modes.
Contacta ahora
Product DescriptionScope of ApplicationIt is suitable for various surgeries on cutting or coagulation, including general surgery, heart, urology, gynecology, anorectal surgery, orthopedics, thoracic surgery, tumor, etc. It is also used with surgeries of endoscope, hysteroscope, laparoscope, ENT endoscope, etc. The bipolar can be used in the fine surgeries of microsurgery, neurology, ENT and ophthalmology, hand surgery,etc.Product Details●Independent output port of endoscope and intelligent conversion key, which can enter endoscopic mode automatically after start-up.
Contacta ahora
Product descriptionThe smoke evacuator is easy to operate and easy to replace filters.
Contacta ahora
Product descriptionApplied in all fields, such as laparoscopy, urology, rectoscopy, otolaryngology, etc1) It is recommended that all rigid and flexible mirrors can be used for diagnosis and surgery2) Combine Sony CMOS high-definition camera with 80W LED light source.3) Equipped with 22 inch high-definition display4) The integrated design of LED cold light source and camera saves space and is convenient to carry;5) Video recording and capture functionsTechnical specificationProduct ModelYKD-9122Camera1/2.8 inch SONY CMOS HD CameraPixels2,100,000 PixelsImage Size(Horizontal*Vertical)1920*10
Contacta ahora
Product Description This transport ventilator is a very important medical equipment that can provide necessary respiratory support to patients in emergency situations. During first aid and transport, even in the event of a power outage, it can help patients maintain normal respiratory function and prevent dangerous situationscaused by insufficient oxygen.FAQQ1.What are your packaging details?A1.
Contacta ahora
Product description This transport ventilator is a very important medical equipment that can provide necessary respiratory support to patients in emergency situations.
Contacta ahora
Product descriptionExperts have identified harmful smoke which contain toxic gases and vapors will occurduring electrosurgical operation.Medical staff and patients exposure to the smoke may cause viral contamination,respiratory problems and burning eyes.To use a smoke evacuation system is themost effective way of protecting operating room staff and patients from hazard.The smoke evacuator is easy to operate and easy to replace filters.
Contacta ahora
Product descriptionThe 416KHz (±10%) high-frequency current generated by this machine can perform surgical operations such as biological tissue cutting and coagulation, and has unipolar cutting: pure cutting, mixed cutting 1, mixed cutting 2; unipolar coagulation: spray coagulation, soft coagulation and standard bipolar six working modes.The output of this machine is fully suspended, with two independently isolated CF-type anti-defibrillation application parts (unipolar and bipolar), non-AP, non-APG type general equipment, 220V±10% or 110V±10% network power supply.Technology parameterRated out
Contacta ahora
Product descriptionType:The output of this machine is fully suspended, with two independent and isolated CF-type anti-defibrillation application parts (unipolar and bipolar), non-AP, APG type ordinary equipment, powered by 220V±10% network power supply.Function:The 416KHz (±10%) high-frequency current generated by this machine can perform surgical operations such as cutting and coagulation of biological tissues. It has the functions of unipolar pure cutting: pure cutting, mixed cutting 1, mixed cutting 2; unipolar coagulation: spray coagulation There are six working modes: , sof
Contacta ahora
Relate News
MODEL30 Anesthesia MachineAnaesthesia main unit:High resolution 5.5" LCD screenClose, semi-close, semi-open systemApplication: Adult, PediatricLow gas alarming: Low O2 gas pressure, it will gives alarming more than 7 seconds.High pressure Limitation: Whenever airway pressure exceed the pre-set High pressure,ventilator offers protection automatically, to assure airway pressure can not increase anymore which supplies safety to patient.Low pressure protection: Once O2 pressure less than 0.1MPa, N2O qas supply was stopped automatically.Power failure alarming.
Anaesthesia Machine MODEL50High resolution 5.5" LCD screenClose, semi-close, semiopen systemApplication: Adult, PediatricLow gas alarming: Low O2 gas pressure, it will gives alarming more than 7 seconds.High pressure Limitation: Whenever airway pressure exceed the pre-set High pressureventilator offers protection automatically, to assure airway pressure can not increase anymore which supplies safety to patient.Low pressure protection: Once O2 pressure less than 0.1MPa, N2O gas supply was stopped automatically.Power failure alarming, power extendable functionO2 flush: 25~ 75 L/minGas Press
Anesthesia Machine Model40High resolution 8”color TFT LCD screenDual-end pressure flow sensor,The unit can monitoring Tidal volume,Respiratory frequency, Airway pressure, Pressure-time wave,High pressure limitation, Low pressure limitation, Apnea,Oxygen concentration under both two operating mode (Auto、Manual)Respiration loop functionClose, semi-close, semi-open systemApplication: Adult, PediatricLow gas alarming: Low O2 gas pressure, it will gives alarming more than 7 seconds.High pressure limitation: Whenever airway pressure exceed the pre-set high pressure,ventilator offers protection autom
Render Medical AGSS DeviceAfter the anesthesia gas from the anesthesia machine is inhaled into the human body, the residual gas is discharged into the surrounding environment. Although it may cause pollution to the air in the operating room, this pollution has not been taken seriously, especially in small hospitals. The AGSS anesthesia exhaust gas emission system optional for imported anesthesia machines is expensive and belongs to the consumption type. Due to departmental cost considerations, it is rarely used.
What is the Difference between High-Frequency Electrocautery and Electrocoagulation?Simply put, it is a surgical knife that generates a high-voltage current at the end of the electric knife pen through the device, which instantly heats the tissue and thus plays a cutting role.For high-frequency electrocautery, the basic functions are electrocautery and electrocoagulation.
Explanation of precautions when using electrosurgical unitElectrosurgical Unit is a device that almost every surgeon will come into contact with. When using it, the following points should be noted:1. Have an understanding of the principles of ESU cutting and coagulation.2. When using a electrosurgical unit, do not select the wrong mode. For example, do not choose the cutting and coagulation modes incorrectly. If you choose the cutting mode during coagulation, it will cause tissue cells to burn and die.3.
The Difference between Electrosurgical Unit and Ultrasonic KnifeThe principle of electrosurgical unit cutting is to generate voltage and current at the tip of the electric knife, and generate high temperature when in contact with the skin to cut tissue.The application principle of ultrasonic knife is to convert electrical energy into mechanical energy through a special conversion device, and the mechanical energy transmitted in the form of sine waves acts on the metal knife head at the front end, causing the knife head to produce 50-100 μ The mechanical oscillation of m amplitude generates fri
The Difference between ESU and Ultrasonic Surgery SystemThe principle of electrosurgical unit cutting is to generate voltage and current at the tip of the electric knife, and generate high temperature when in contact with the skin to cut tissue.The application principle of ultrasonic knife is to convert electrical energy into mechanical energy through a special conversion device, and the mechanical energy transmitted in the form of sine waves acts on the metal knife head at the front end, causing the knife head to produce 50-100 μ.The mechanical oscillation of m amplitude generates frictional
Ventilator Gas Switching Mode    Different types of ventilators have different ways of converting the inspiratory phase and the expiratory phase. At present, there are mainly four forms of breathing phase switching in ventilators, the most basic of which are pressure switching and volume switching.    1. Time switching.     Negative pressure ventilators use time switching. Modern time-switched ventilators are controlled by electronic circuits.
Argon Plasma ESUTechnical Parameters:a) Ambient temp.range: 50℃ - 40℃;b) Relative Humidity Range: ≤80c)Atmospheric Pressure Range: 86.0-106.0kpad) Power:220V±22V,50Hz±1 or110V±11V,60Hz±1;e)Operating Freg.:416kHz;f)Rated Power:≤1100VA(Cut function 350W)g) Type: CF,Non-AP、Non-APG typeWoking modes comply with Argon Plasma function:a) Pure Cut:1W-300W(Load 500Ω) b)Blend 1:1W-200W(Load 500Ω)c)Blend 2:1W-150W(Load 500Ω)d) ENDO Cut:99%(Load 500Ω)e)Spray Coag.:1W-80W (Load 500Ω)f)Desicate Coag.:1W-120W (Load 500Ω)g) BI-Coag:1W-70W (Load 100Ω) (optional)h)Argon: Dual Argon airflow adjustment,