Electrical Operating Table-manufacture,factory,supplier from China

(Total 24 Products for Electrical Operating Table)
Product descriptionApplicable for general surgery, thoracic surgery, orthopedics, obstetrics and gynecology, urologic surgery, cerebral surgery,microsurgery, ENT surgery and etcCUT MODEPure Cut: High-frequency alternating current produces smooth, fast cuts that induce little-understood hemostasis Mix 1: Preset Mix Cut Modes provide surgeons with varying degrees of hemostasis in cut mode. Mix 2: This mode is used for vaporization of prostate tissue or any fatty tissue. Higher output wattage gives rapid tissue cutting effect.
Contacta ahora
Product DescriptionMedical High Frequency Electrosurgical Unit with isolated output design, it provides proper power output for cutting and coagulating tissue in both monopolar and bipolar surgeries.It can meet the needs of many surgical operations. Adopting singlechip microcomputer control technology and modular design, it features simple design, convenient maintenance,powerful functions, stable performance and easy operation and is equipped with versatile jacks for accessories.Technology parameterRated output power:Pure cut: 1W~350W (Max.
Contacta ahora
Product descriptionCompact structure, beautiful and exquisite, saving operating room spaceStainless steel table top, never rust, reduce maintenance costsTechnology specificationAnaesthesia main unit:■High luminance digital LED screen■Close,semi-close,semi-open system■Application:Adult,Pediatric■Low gas alarming:Low O2 gas pressure,it will give alarming more than 7 seconds■High pressure limitation:Whenever airway pressure exceed the pre-set high pressure,ventilator offers protection automatically, to assure airway pressure can not increase anymore which supplies safety to patient.■Power failure
Contacta ahora
Product DescriptionAnesthetic Gas Scavenging System (AGSS) is a device used to remove anesthetic gases generated in operating rooms or other medical environments.Anesthetic gas is a medication used during surgery, usually delivered to patients through an anesthesia machine.However, some anesthesia gases may leak into the air of the operating room, posing potential health risks to medical staff and patients.The main function of AGSS is to collect and discharge anesthesia gases from the operating room through inhalation and filtration,in order to reduce the risk of personnel exposure to these ga
Contacta ahora
Product Details:Technical Parameters:1. Ambient temp. range: 5ºC~40 ºC;2. Relative Humidity Range: ≤80;3. Atmospheric Pressure Range: 86.0~106.0kpa;4. Power: 220V±22V,50Hz±1;5. Operating Freq.: 330~460kHz;6. Rated Power: 1100VA±10%;7. Type: CFPower Consumption: ≤1100VA (Cut function 400) Transportation and Storage:a),Ambient Temp.
Contacta ahora
Product DescriptionAnesthesia machines have shown good performance in intensive care units (ICU), operating rooms, anesthesia departments, and other departments. Our expertise in anesthesia delivery and ventilation is based on a rich 15 year history of developing anesthesia solutions to meet your needs.
Contacta ahora
Product descriptionExperts have identified harmful smoke which contain toxic gases and vapors will occurduring electrosurgical operation.Medical staff and patients exposure to the smoke may cause viral contamination,respiratory problems and burning eyes.To use a smoke evacuation system is themost effective way of protecting operating room staff and patients from hazard.The smoke evacuator is easy to operate and easy to replace filters.
Contacta ahora
Product descriptionAnesthesia machines have shown good performance in intensive care units (ICU), operating rooms, anesthesia departments, and other departments. Our expertise in anesthesia delivery and ventilation is based on a rich 15 year history of developing anesthesia solutions to meet your needs.
Contacta ahora
Product descriptionAnesthesia machines have shown good performance in intensive care units (ICU), operating rooms, anesthesia departments and other departments. Our expertise in anesthesia delivery and ventilation is based on a rich 15-year history of developing anesthesia solutions to meet your needs.
Contacta ahora
Technical SpecificationAnaesthesia main unit:High resolution 10.4" color TFT LCD screenDual-end pressure flow sensor,The unit can monitoring Tidal Volume,Respiratory frequency, airway pressure, pressure-time wave, flow-time wave (two-way),High Pressure limitation, Low Pressure limitation, Apnea,Oxygen concentration under both two operating mode (Auto、Manual)Respiration loop functionClose,semi-close,semi-openApplication: Adult, PediatricLow gas alarming: it gives alarming more than 7 seconds.High pressure Limitation: Whenever airway pressure exceed the pre-set High pressure,ventilator offe
Contacta ahora
Product descriptionContains Output interface for Anesthesia information management system.Complete with backup battery for working more than 120 minutes.Technology specification■High resolution 10.4'' TFT  LCD screen■Dual-end pressure flow sensor,The unit can monitoring tidal volume,respiratory frequency,airway pressure,pressure-time wave,flow-time wave(two-way),high pressure limitation,low pressurelimitation,apnea,oxygen concentration under both two operating mode(Auto,Manual)■Respiration loop function■Close,semi-close,semi-open and open(with bain circuit)■Application:Adult,
Contacta ahora
Product descriptionContains Output interface for Anesthesia information management system.Complete with backup battery for working more than 30 minutes.Technical SpecificationAnaesthesia main unit:■High resolution 8'' color TFT LCD screen■Dual-end pressure flow sensor,The unit can monitoring Tidal volume,Respiratory frequency,Airway pressure,Presssure-time wave,High pressure limitation,Low pressure Limitation,Apnea,Oxygen concentration under both operating mode(Auto,Manual)■Respiration loop function■Close,semi-close,semi-open system■Application:Adult,Pediatric■Low gas alarming:Low
Contacta ahora
Product descriptionModel S Anaesthesia Machine contains output interface for anesthesia information management system. Complete with backup battery for working more than 120 minutes.Product ParameterDual-end pressure flow sensor,The unit can monitoring tidal volume,respiratory frequency,airway pressure,pressure-time wave,flow-time wave(two-way),high pressure limitation,low pressure limitation,apnea,oxygen concentration under both two operating mode(Auto,Manual)Respiration loop functionClose,semi-close,semi-open and open(with bain circuit)Low gas alarming:it gives alarming more than 7
Contacta ahora
Product Features1/2.8 Sony CMOS Full HD Image Sensor;Built in 19 inch high-definition display, displaying more tissue details to ensure surgical safety;Integrated design of LED cold light source and camera, saving space and easy to carry;Built-in USB full HD image storage, photo capture/video recording function;IPX8 waterproof camera.Technical ParametersCamera1/2.8inch SONY CMOS HD CameraPixel2100,000 pixelsImage size(Horizontal×Vertical)1920×1080Scanning systemProgressive ScanningFrame rate(1920×1080)60pSNR60dB Tolerance 20%Horizon resolution1080 TVL Tolerance 20%Monitor19 inch HD medica
Contacta ahora
Product description This transport ventilator is a very important medical equipment that can provide necessary respiratory support to patients in emergency situations.
Contacta ahora
Procuct descriptionThis transport ventilator is a very important medical device that can provide patients with necessary breathing support in an emergency.
Contacta ahora
Product DescriptionVeterinary anesthesia systems are widely used in veterinary clinics, hospitals and laboratories and continue to be well received by customers around the world.The SD-M2000A(P) model is designed for safe, simple, and controlled inhalation anesthesia in animals. Veterinary anesthesia systems provide rapid control of depth of anesthesia, low respiratory resistance, acuity from high to low, simple to complex cases, small to large animals such as dogs, cats, rabbits, mice, birds, etc.Technical SpecificationAnaesthesia main unit:Working Mode: ManualWorking method: Close,
Contacta ahora
Product Description This transport ventilator is a very important medical equipment that can provide necessary respiratory support to patients in emergency situations. During first aid and transport, even in the event of a power outage, it can help patients maintain normal respiratory function and prevent dangerous situationscaused by insufficient oxygen.FAQQ1.What are your packaging details?A1.
Contacta ahora
Product description This transport ventilator is a very important medical device that can provide patients with necessary breathing support in an emergency.
Contacta ahora
Product descriptionThe smoke evacuator is easy to operate and easy to replace filters.
Contacta ahora
Product descriptionApplicable for general surgery, thoracic surgery, orthopedics, obstetrics and gynecology, urologic surgery, cerebral surgery,microsurgery, ENT surgery and etcCUT MODEPURE CUT:A high-frequency alternating current yields smooth, rapid cuts that evoke little to know hemostasisBLEND 1:Preset blended cut modes give the surgeon varying degrees of hemostasis in cut mode.BLEND 2:The mode is used for vaponzation of prostatic tissue or any fat tissue.
Contacta ahora
Product descriptionSD-M2000A(P) Veterinary anesthesia machines are reliable professional equipment for small animal anesthesia. Easy installation and maintenance, saving space.
Contacta ahora
Product DescriptionUsed for Monopolar and Bipolar surgery in many surgical fields.Microprocessor control and digital display in LED panel.System has return electrode monitoring(REM) system.Support in underwater cut operation.Full-function automatic power compensation.System has a universal endoscope interface, which is used with gastroscope, enteroscope, bronchoscope,laparoscope and other endoscopes.Support bipolar closure and separation to meet the reguirements of surgical bipolar treatment without sticking the negative plate.Patient circuit bipolar electrode plate contact quality detect
Contacta ahora
Product descriptionRemote fault diagnosis.Human voice alarm function.Full-function automatic power compensation.System has return electrode monitoring (REM) system.Microprocessor control and digital display in LED panel.Used for Monopolar and Bipolar surgery in many surgical fields.Support bipolar closure and separation to meet the requirements of surcical bipolar treatment withoutsticking the negative plate.System has a universal endoscope interface, which is used with gastroscope, enteroscope, bronchoscope,aparoscope and other endoscopes.This machine has a power-off protection circuit, which
Contacta ahora
Relate News
What to do if there is no output when the ESU Unit is started and turned on?The ESU Unit has long been widely used as an electrical surgical equipment in surgery. Once there are problems with the ESU Unit during surgery, it will inevitably affect the surgical process.
The Principle and Applicability of Bipolar Electrosurgical UnitHigh frequency surgical unit is divided into monopolar and bipolar. monopolar high-frequency surgical unit forms a circuit between the negative electrode plate and the knife pen. The following introduces the working principle and applicable surgery of bipolar electric knife:The principle of bipolar high-frequency electric knife is to provide high-frequency electrical energy to the body tissue through the two tips of bipolar forceps,causing the blood vessels between the two ends of the bipolar forceps to dehydrate and coag
The Difference between Electrosurgical Unit and Ultrasonic KnifeThe principle of electrosurgical unit cutting is to generate voltage and current at the tip of the electric knife, and generate high temperature when in contact with the skin to cut tissue.The application principle of ultrasonic knife is to convert electrical energy into mechanical energy through a special conversion device, and the mechanical energy transmitted in the form of sine waves acts on the metal knife head at the front end, causing the knife head to produce 50-100 μ The mechanical oscillation of m amplitude generates fri
The Difference between ESU and Ultrasonic Surgery SystemThe principle of electrosurgical unit cutting is to generate voltage and current at the tip of the electric knife, and generate high temperature when in contact with the skin to cut tissue.The application principle of ultrasonic knife is to convert electrical energy into mechanical energy through a special conversion device, and the mechanical energy transmitted in the form of sine waves acts on the metal knife head at the front end, causing the knife head to produce 50-100 μ.The mechanical oscillation of m amplitude generates frictional
Render Medical AGSS DeviceAfter the anesthesia gas from the anesthesia machine is inhaled into the human body, the residual gas is discharged into the surrounding environment. Although it may cause pollution to the air in the operating room, this pollution has not been taken seriously, especially in small hospitals. The AGSS anesthesia exhaust gas emission system optional for imported anesthesia machines is expensive and belongs to the consumption type. Due to departmental cost considerations, it is rarely used.
Argon Plasma ESUTechnical Parameters:a) Ambient temp.range: 50℃ - 40℃;b) Relative Humidity Range: ≤80c)Atmospheric Pressure Range: 86.0-106.0kpad) Power:220V±22V,50Hz±1 or110V±11V,60Hz±1;e)Operating Freg.:416kHz;f)Rated Power:≤1100VA(Cut function 350W)g) Type: CF,Non-AP、Non-APG typeWoking modes comply with Argon Plasma function:a) Pure Cut:1W-300W(Load 500Ω) b)Blend 1:1W-200W(Load 500Ω)c)Blend 2:1W-150W(Load 500Ω)d) ENDO Cut:99%(Load 500Ω)e)Spray Coag.:1W-80W (Load 500Ω)f)Desicate Coag.:1W-120W (Load 500Ω)g) BI-Coag:1W-70W (Load 100Ω) (optional)h)Argon: Dual Argon airflow adjustment,
CM-350ATechnical Parameters:a) Ambient temp.range: 50℃ - 40℃;b) Relative Humidity Range: ≤80c)Atmospheric Pressure Range: 86.0-106.0kpad) Power:220V±22V,50Hz±1 or110V±11V,60Hz±1;e)Operating Freg.:416kHz;f)Rated Power:≤1100VA(Cut function 350W)g) Type: CF,Non-AP、Non-APG typeOutput modesa) Pure Cut:1W-350W(Max.400W,Load 500Ω) b)Blend 1:1W-250W(Load 500Ω)c)Blend 2:1W-200W(Load 500Ω)d) Blend 3:1W-150W(Load 500Ω)e)ENDO Cut:99%(Load 500Ω)f)Spray Coag.:1W-80W (Load 500Ω)g) Force Coag.:1W-120W (load 500 Ω)h) Desicate Coag.:1W-120W (Load 500Ω)i)BI-Coag:1W-70W (Load 100Ω)j)Auto-Coag.:1W-70W (Load 1
Introduction to Electrosurgical UnitWhat is a ESU?Electrosurgical Unit is widely used in various surgeries, for tissue cutting and coagulation, and is one of the essential equipment in the operating room.What do the parameters of ESU mean?Electrosurgical Units are divided into monopolar and bipolar modes, and in monopolar mode, they must be used together with the negative electrode plate (neutral electrode plate). Let the current released by the blade flow back to the electric knife through the negative electrode plate to form a closed loop, so as not to burn the human body.
Anesthesia Machine Model40High resolution 8”color TFT LCD screenDual-end pressure flow sensor,The unit can monitoring Tidal volume,Respiratory frequency, Airway pressure, Pressure-time wave,High pressure limitation, Low pressure limitation, Apnea,Oxygen concentration under both two operating mode (Auto、Manual)Respiration loop functionClose, semi-close, semi-open systemApplication: Adult, PediatricLow gas alarming: Low O2 gas pressure, it will gives alarming more than 7 seconds.High pressure limitation: Whenever airway pressure exceed the pre-set high pressure,ventilator offers protection autom
Argon Plasma ESU Clinical Application(1) SurgeryA. Application of General Surgery and Hepatobiliary Surgery: The argon plasam is particularly suitable for surgeries involving substantial organs and large areas of bleeding. The argon ion beam scans back and forth on the wound, and the argon airflow can blow away blood, making the surgical field of view clearer. Thus achieving a hemostatic effect.B.
x

Enviado satisfactoriamente

Nos pondremos en contacto con usted tan pronto como sea posible

Cerca