Biphasic defibrillation-manufacture,factory,supplier from China

(Total 24 Products for Biphasic defibrillation)
Product descriptionType:The output of this machine is fully suspended, with two independent and isolated CF-type defibrillation-proof application parts (unipolar and bipolar), non-AP, APG-type common equipment, 220V±10% mains power supply.Function:The 416KHz (±10%) high-frequency current generated by this machine can perform surgical operations such as cutting and coagulation on biological tissues.
Contacta ahora
Product descriptionThe 416KHz (±10%) high-frequency current generated by this machine can perform surgical operations such as biological tissue cutting and coagulation, and has unipolar cutting: pure cutting, mixed cutting 1, mixed cutting 2; unipolar coagulation: spray coagulation, soft coagulation and standard bipolar six working modes.The output of this machine is fully suspended, with two independently isolated CF-type anti-defibrillation application parts (unipolar and bipolar), non-AP, non-APG type general equipment, 220V±10% or 110V±10% network power supply.Technology parameterRated out
Contacta ahora
Product descriptionThe 416KHz (± 10%) high frequency current generated by this machine can perform surgical operations such as cutting and coagulation of biological tissues, and has monopolar cut: pure cut, blend cut 1, blend cut 2; Monopolar coagulation: spray coagulation, soft coagulation and standard bipolar six working modes.The output of this machine is fully suspended, with two independent and isolated CF type anti-defibrillation application parts (Monopolar and Bipolar), Non-AP、Non-APG type common equipment, and 220V ± 10% or 110V ± 10% network power supply.Technology parameterRated out
Contacta ahora
Product descriptionType:The output of this machine is fully suspended, with two independent and isolated CF-type anti-defibrillation application parts (unipolar and bipolar), non-AP, APG type ordinary equipment, powered by 220V±10% network power supply.Function:The 416KHz (±10%) high-frequency current generated by this machine can perform surgical operations such as cutting and coagulation of biological tissues. It has the functions of unipolar pure cutting: pure cutting, mixed cutting 1, mixed cutting 2; unipolar coagulation: spray coagulation There are six working modes: , sof
Contacta ahora
Product descriptionApplicable for general surgery, thoracic surgery, orthopedics, obstetrics and gynecology, urologic surgery, cerebral surgery,microsurgery, ENT surgery and etcCUT MODEPURE CUT:A high-frequency alternating current yields smooth, rapid cuts that evoke little to know hemostasisBLEND 1:Preset blended cut modes give the surgeon varying degrees of hemostasis in cut mode.BLEND 2:The mode is used for vaponzation of prostatic tissue or any fat tissue.
Contacta ahora
Product descriptionThis endoscope camera is equipped with Sony CCD sensors, focusing on high-quality images with a large number of pixels, low noise, and excellent photosensitivity. Its compact design helps users easily carry it for emergency situations or basic OPD use.
Contacta ahora
Product DescriptionScope of ApplicationIt is suitable for various surgeries on cutting or coagulation, including general surgery, heart, urology, gynecology, anorectal surgery, orthopedics, thoracic surgery, tumor, etc. It is also used with surgeries of endoscope, hysteroscope, laparoscope, ENT endoscope, etc. The bipolar can be used in the fine surgeries of microsurgery, neurology, ENT and ophthalmology, hand surgery,etc.Product Details●Independent output port of endoscope and intelligent conversion key, which can enter endoscopic mode automatically after start-up.
Contacta ahora
Product DescriptionUsed for Monopolar and Bipolar surgery in many surgical fields.Microprocessor control and digital display in LED panel.System has return electrode monitoring(REM) system.Support in underwater cut operation.Full-function automatic power compensation.System has a universal endoscope interface, which is used with gastroscope, enteroscope, bronchoscope,laparoscope and other endoscopes.Support bipolar closure and separation to meet the reguirements of surgical bipolar treatment without sticking the negative plate.Patient circuit bipolar electrode plate contact quality detect
Contacta ahora
Product descriptionSD-M2000A(P) Veterinary anesthesia machines are reliable professional equipment for small animal anesthesia. Easy installation and maintenance, saving space.
Contacta ahora
Product Description1. 7" screen displays information area, alarm area, monitoring area, and setting area. 2. High precision mechanical flowmeter, instantly know the fresh gas flow to animals. 3. Vaporizer with temperature, pressure, flow compensation and self-lock function, keep safety anytime. 4. Real time pressure-time, flow-time oscillogram 5. Manual and mechanical ventilation for safer operation.6. External sensor design makes parameters setting more accurate. 7.
Contacta ahora
Technical SpecificationAnaesthesia main unit:High resolution 10.4" color TFT LCD screenDual-end pressure flow sensor,The unit can monitoring Tidal Volume,Respiratory frequency, airway pressure, pressure-time wave, flow-time wave (two-way),High Pressure limitation, Low Pressure limitation, Apnea,Oxygen concentration under both two operating mode (Auto、Manual)Respiration loop functionClose,semi-close,semi-openApplication: Adult, PediatricLow gas alarming: it gives alarming more than 7 seconds.High pressure Limitation: Whenever airway pressure exceed the pre-set High pressure,ventilator offe
Contacta ahora
Product descriptionCompact structure, beautiful and exquisite, saving operating room spaceStainless steel table top, never rust, reduce maintenance costsTechnology specificationAnaesthesia main unit:■High luminance digital LED screen■Close,semi-close,semi-open system■Application:Adult,Pediatric■Low gas alarming:Low O2 gas pressure,it will give alarming more than 7 seconds■High pressure limitation:Whenever airway pressure exceed the pre-set high pressure,ventilator offers protection automatically, to assure airway pressure can not increase anymore which supplies safety to patient.■Power failure
Contacta ahora
Product description This transport ventilator is a very important medical device that can provide patients with necessary breathing support in an emergency.
Contacta ahora
Product descriptionLigasure is also called high frequency surgical system, and ligasure is widely used in various surgical operations. Compared with traditional electrosurgical equipment, ligasure has the function of cutting blood coagulation and sealing 7 mm large blood vessels.FAQQ1. What is the advantage about your company?A1.The company has been engaged in export business for more than 15 years, with a professional team and professional production line.Q2.
Contacta ahora
Product descriptionThe 416KHz (±10%) high frequency current generated by the machine can be used for biological tissue cutting, coagulation and other surgical operations, and has unipolar cutting: pure cutting, mixed cutting 1, mixed cutting 2; Unipolar solidification: spray solidification, soft solidification and standard bipolar six working modes.
Contacta ahora
CM-350A meets the surgeon's needs in the wide range of general procedures and in special ties including Gynecology, Urology, Neurology, Thorasic, plastic and Reconstructive surgery. It has spray coagulation which rivals the best spark gap generators and with minimum cutting effect.
Contacta ahora
Product descriptionRENDER CM-350 Ar and its special probes offers fundamental advantages over conventional coagulation methods.The Argon Plasma beam permits non-contact coagulation of tissue, homeostasis of large surface bleeding can be stopped effectively and safely.
Contacta ahora
Product description This transport ventilator is a very important medical equipment that can provide necessary respiratory support to patients in emergency situations.
Contacta ahora
Procuct descriptionThis transport ventilator is a very important medical device that can provide patients with necessary breathing support in an emergency.
Contacta ahora
Product descriptionRemote fault diagnosis.Human voice alarm function.Full-function automatic power compensation.System has return electrode monitoring (REM) system.Microprocessor control and digital display in LED panel.Used for Monopolar and Bipolar surgery in many surgical fields.Support bipolar closure and separation to meet the requirements of surcical bipolar treatment withoutsticking the negative plate.System has a universal endoscope interface, which is used with gastroscope, enteroscope, bronchoscope,aparoscope and other endoscopes.This machine has a power-off protection circuit, which
Contacta ahora
Product descriptionWOWO200 anesthesia ventilator is an very exellent machine.lt has many ventilation mode, waveform display, parameters setting and parameters alarm.lt can match different anesthesia machine. After using WOWO200 anesthesia ventilator, the feedback of hospitals is very exellent.FAQQ1. How long is the warranty period?A1.24 months.Q2.What is the payment method?A2.TT, L/C, etc.Q3.When will you deliver the goods?A3.Usually 7-30 days.Q4.
Contacta ahora
Product descriptionBuilt in 8'' color anaesthesia ventilatorNew compact CO2 absorber(autoclavable,Patent)high end precise vaporizer(volume>280ml,Patent)Battery back up for all system over 60 mins,bain circuit interfaceOptional:Touch screen anaesthesia ventilatorOptional:Anaesthesia gas scavenging systemOptional:Yoke system,electronic tidal volume(Innovation)Optional:Continuous FIO2 monitoring, EtCO2 monitoring functionOptional:Built-in air compressor or Air/O2 inter-link system(innovation)Technical ParameterProduct nameModel no. MOQ Q'ty MeasurementG.W.
Contacta ahora
IntroductionAnaesthesia main unit:High resolution 5.5''  LCD screenClose,semi-close,semi-open systemApplication:Adult,PediatricLow gas alarming:Low O2 gas pressure,it will give alarming more than 7 secondsHigh pressure limitation:Whenever airway pressure exceed the pre-set high pressure,ventilator offers protection automatically, to assure airway pressure can not increaseanymore which supplies safety to patient.Low pressure protection:Once O2 pressure less than 0.1MPa, N2O gas supply was stoppedautomatically.Power failure alarming, power extendable function02 flush: 25~75 L/minGas
Contacta ahora
Product DescriptionVeterinary anesthesia systems are widely used in veterinary clinics, hospitals and laboratories and continue to be well received by customers around the world.The SD-M2000A(P) model is designed for safe, simple, and controlled inhalation anesthesia in animals. Veterinary anesthesia systems provide rapid control of depth of anesthesia, low respiratory resistance, acuity from high to low, simple to complex cases, small to large animals such as dogs, cats, rabbits, mice, birds, etc.Technical SpecificationAnaesthesia main unit:Working Mode: ManualWorking method: Close,
Contacta ahora
Relate News
Is Oral and Dental Electrosurgical Unit Specialized?Electrosurgical Unit are widely used in general surgery, cosmetic plastic surgery, and various minimally invasive surgeries due to their excellent cutting and coagulation abilities.
CM-350C Electrosurgical UnitUsed for Monopolar and Bipolar surgery in many surgical fields.Microprocessor control and digital display in LED panel.System has return electrode monitoring (REM) system.Support in underwater cut operation.Full-function automatic power compensation.System has a universal endoscope interface, which is used with gastroscope, enteroscope, bronchoscope,aparoscope and other endoscopes.Support bipolar closure and separation to meet the requirements of surgical bipolar treatment without sticking the negative plate.Patient circuit bipolar electrode plate contact quality de
Application of Electrosurgical Unit in Oral Tissue Repair      Electrosurgical Unit is the use of high-frequency alternating current technology to generate thermal effects within tissues and selectively destroy certain tissues. The radio frequency energy emitted by the host is concentrated in the electrodes, forming a complete circuit through the human body, reflux plate, and its circuit. According to different usage purposes, energy output can be divided into fully rectified output and partially rectified output.
The Difference between ESU and Ultrasonic Surgery SystemThe principle of electrosurgical unit cutting is to generate voltage and current at the tip of the electric knife, and generate high temperature when in contact with the skin to cut tissue.The application principle of ultrasonic knife is to convert electrical energy into mechanical energy through a special conversion device, and the mechanical energy transmitted in the form of sine waves acts on the metal knife head at the front end, causing the knife head to produce 50-100 μ.The mechanical oscillation of m amplitude generates frictional
Introduction to Electrosurgical UnitWhat is a ESU?Electrosurgical Unit is widely used in various surgeries, for tissue cutting and coagulation, and is one of the essential equipment in the operating room.What do the parameters of ESU mean?Electrosurgical Units are divided into monopolar and bipolar modes, and in monopolar mode, they must be used together with the negative electrode plate (neutral electrode plate). Let the current released by the blade flow back to the electric knife through the negative electrode plate to form a closed loop, so as not to burn the human body.
Argon Plasma Electrosurgical UnitFull-function automatic power compensation.Both hand control and foot control outputs are available.Triple foot switch is controlled independently, convenient and fast.This machine has a power-off protection circuit, which can memorize the output set value of each function in real time.Adopt ENDO CUT alterative output endoscope mode to provide safe and optimal coagulation efect under endoscope.Output 10 groups of memory modes, support endoscopic treatment,ESD, ERCP, polypectomy and other operations.With adjustable high-frequency pulse cutter system, the damage
Render Medical AGSS DeviceAfter the anesthesia gas from the anesthesia machine is inhaled into the human body, the residual gas is discharged into the surrounding environment. Although it may cause pollution to the air in the operating room, this pollution has not been taken seriously, especially in small hospitals. The AGSS anesthesia exhaust gas emission system optional for imported anesthesia machines is expensive and belongs to the consumption type. Due to departmental cost considerations, it is rarely used.
Argon Plasma ESUTechnical Parameters:a) Ambient temp.range: 50℃ - 40℃;b) Relative Humidity Range: ≤80c)Atmospheric Pressure Range: 86.0-106.0kpad) Power:220V±22V,50Hz±1 or110V±11V,60Hz±1;e)Operating Freg.:416kHz;f)Rated Power:≤1100VA(Cut function 350W)g) Type: CF,Non-AP、Non-APG typeWoking modes comply with Argon Plasma function:a) Pure Cut:1W-300W(Load 500Ω) b)Blend 1:1W-200W(Load 500Ω)c)Blend 2:1W-150W(Load 500Ω)d) ENDO Cut:99%(Load 500Ω)e)Spray Coag.:1W-80W (Load 500Ω)f)Desicate Coag.:1W-120W (Load 500Ω)g) BI-Coag:1W-70W (Load 100Ω) (optional)h)Argon: Dual Argon airflow adjustment,
Anesthesia Machine Model40High resolution 8”color TFT LCD screenDual-end pressure flow sensor,The unit can monitoring Tidal volume,Respiratory frequency, Airway pressure, Pressure-time wave,High pressure limitation, Low pressure limitation, Apnea,Oxygen concentration under both two operating mode (Auto、Manual)Respiration loop functionClose, semi-close, semi-open systemApplication: Adult, PediatricLow gas alarming: Low O2 gas pressure, it will gives alarming more than 7 seconds.High pressure limitation: Whenever airway pressure exceed the pre-set high pressure,ventilator offers protection autom
Can a Ventilator on Anesthesia Replace a Dedicated Ventilator?After the outbreak of the epidemic abroad in March this year, the demand for ventilators increased significantly. Faced with a large demand from abroad, domestic respirator manufacturers have reached saturation in production capacity but still cannot meet the strong demand. So much so that many people pay attention to anesthesia machines, which are also equipped with ventilators and have similar breathing patterns. Can anesthesia machines replace ventilators?
x

Enviado satisfactoriamente

Nos pondremos en contacto con usted tan pronto como sea posible

Cerca